Home About Us Contact
 


An
ISO 9001:2000
ISO 13485:2003
Certified Company

BIS & AERB Approved

 
60mA & 100 mA
 
60mA - 100mA FULLY RECTIFIED DIAGNOSTIC X-RAY SYSTEMS
 
Incorporated with the latest full wave X-Ray technology is very useful for all the radiographic and fluroscopic requirements for small nursing Homes, Hospitals and clinics as Stationary and Mobile X-Ray systems.
 
SALIENT FEATURES
  • Fullwave rectification which delivers almost double the output than the self rectified X-Ray systems. Full wave rectifications with high voltage silicon rectifier for low losses and consistent radiographic results.
  • Smoothening circuit provides maximum mA output accuracy at all time settings.
  • Full field light bean Collimator - for proper positioning and preventing accidental cut off the field.
  • Continuous fluoroscopic timer by pressing F_RST push button. (100mA)
  • Low output power station 4Kw, for versatile generator, in absence of power-line. ( 100mA)
  • Double mA range meter with lamp. (100mA).

OPTIONS
The following combination are offered :-
 
 
  • Eco Mobile - Fully counter balanced, very compact-space saver
  • Articulated Tube Head Arms to position the Tube Head for all possible radiographic positions . Fully counter balanced Tube Head for ease of handling with 360 rotation for column .
  • Floor to Ceiling column with straight cross arm -Ideal for radiographic work.
  • Floor to ceiling column with 'U' arm provides screening & with SFD - provides spot filming.
  • One position diagnostic table with / without Bucky.
  • Five position diagnostic table having 0,30,60,90 & -15 trendelenberg position.
 

SPECIFICATIONS OF GENERATOR
 
   
SPECIFICATION PICKS 6010 PICKS 1010 SA/RA
Type of Generator Fullwave Rectified Fullwave Rectified
Output Power 4.8Kw 8Kw
Tube Head Type Self Contained Self Contained
RAD.mA (max) 60mA 100mA
RAD.KVP 40 to 100 40 to 100
KVP Steps 2 KVP 2 KVP
RAD.MA Station 20,40,50,60 40,60,80,100
RAD. Timer 0.02 to 5 sec. in 23 steps 0.02 to 5 sec. in 23 steps
Digital Display mA,mAS & KVP mA,mAS & KVP
X-Ray Tube BEL-DSA-3 or Imported Equivalent BEL-DSA-3 BEL-DRA-6 or Imported Equivalent resp
Fluoroscopy 0 to 3mA 0 to 3mA
Indications Line ON, X-Ray ON Overload Line ON, X-Ray ON Overload
Hand Switch ( For Exposure) Light Beam Diaphragm (Collimator) Provided
Manual LBD Provided
Provided
Manual LBD Provided
Input Power 230 A.C. 50Hz Single Phase 220/415/A.C. 50Hz, 1/3 Phase
FCC with 5 position table
Leg Mobile
Base Mobile

 

Copyright 2004 PICKS MEDICAL SYSTEMS LTD. Design & Managed by Matrix Consulting Services